Sign In | Join Free | My howtoaddlikebutton.com
China Xi'an Xu&Hui Electromechanical Technology Co., Ltd. logo
Xi'an Xu&Hui Electromechanical Technology Co., Ltd.
Verified Supplier

2 Years

Home > Transformer Tester >

Transformer Characteristic Tester for Capacity and Loss Measurement

Xi'an Xu&Hui Electromechanical Technology Co., Ltd.
Trust Seal
Verified Supplier
Credit Check
Supplier Assessment
Contact Now

Transformer Characteristic Tester for Capacity and Loss Measurement

Brand Name : XZH TEST

Model Number : XHTX1318

Certification : CE/ISO

Place of Origin : China

MOQ : 1 Unit

Payment Terms : T/T

Supply Ability : 1,000 units per year

Delivery Time : 5-8 work days

Packaging Details : wooden packaging

Contact Now

XHTX1318 series transformer characteristic tester is a multi-function measuring instrument, which is equivalent to two kinds of test instruments: transformer capacity tester + transformer characteristic parameter tester. It can accurately measure a series of power frequency parameters such as capacity, type, no-load current, no-load loss, short-circuit (load) loss, and impedance voltage of various transformers. XHTX1318 series transformer characteristic tester has many advantages such as small size, light weight, high accuracy, good stability and simple operation. It can completely replace the method of measuring transformer loss and capacity by using many different meters in the past. The wiring is simpler, the test and recording are more convenient, and your work efficiency has been greatly improved.


Transformer Characteristic Tester for Capacity and Loss Measurement

Main features:

1.Accurately measure the capacity of various distribution transformers.

2. It can measure the no-load current, no-load loss, short-circuit voltage and short-circuit (load) loss .

3. The instrument automatically switches the range in the instrument, the test voltage and current range is wide and the wiring is simple. 4. When doing the no-load and load test of the three-phase transformer, the instrument can automatically judge whether the wiring is correct, and display a vector diagram of the three-phase voltage and current.

5. The completion of the single machine can be measured by the load test under the full current of the distribution transformer below 1000KVA; the load test of the distribution transformer below 3150KVA can be completed under one-third of the rated current (at one-third of the rated Under current, the instrument can be converted to the load loss parameter at rated current).

6. All test results are automatically corrected.

7. 320x240 large screen, high brightness LCD display, full Chinese/English menu and operation .

8. The instrument can preset 40 sets of test sample parameters by the user, and these parameters can be deleted and added at any time as needed.

9. With a real-time electronic clock, automatic recording of the date and time of the test.

10. Panel type thermal printer, can quickly print test results on the spot.

11. Data (test sample setting, measurement result, test time, etc.) with power-down storage and browsing function, can store 500 sets of experimental results, and can transmit data online with the computer.

12. The external voltage transformer and current transformer can be used for extended range measurement, and the test object of any parameter can be measured.

Transformer Characteristic Tester for Capacity and Loss MeasurementTransformer Characteristic Tester for Capacity and Loss MeasurementTransformer Characteristic Tester for Capacity and Loss Measurement


Environmental conditions Temperature: -5 °C ~ 40 °C Relative humidity: <95% (25 °C) Altitude: <2500m External interference: no special strong vibration, no special electromagnetic field External power supply: 220VAC±10%, 45Hz~55Hz
Test range Capacity: 10KV oil immersed, dry transformer: 30KVA ~ 2500KVA
35KV oil immersed transformer: 50KVA ~ 31500KVA
20KV dry type transformer: 50KVA ~ 2500KVA
35KV dry type transformer: 50KVA~2000KVA
Voltage: 0 ~ 450V (phase voltage), 0 ~ 1000V (line voltage),
the instrument automatically switches the range internally
Current: 0~100A, the instrument automatically switches the range internally.
Frequency: 45Hz ~ 65Hz
Test accuracy Voltage: 20~100V, ±0.2% FS; 100~450V, ±0.2%
Current: 0.5~10A, ±0.2% FS; 10~100A, ±0.2%
Power: ±0.5% (CosΦ>0.1), ±1.0% (0.02<CosΦ<0.1)
Insulation strength The insulation resistance of the voltage and current input terminals to the housing is ≥100MΩ. The working power input end is subjected to a power frequency of 2KV (effective value) between the outer housings, and it takes 1 minute to test.
Size 400 × 300 × 220mm
Weight 10kg



Product Tags:

transformer capacity tester with warranty

      

transformer loss measurement device

      

transformer characteristic tester for diagnostics

      
Wholesale Transformer Characteristic Tester for Capacity and Loss Measurement from china suppliers

Transformer Characteristic Tester for Capacity and Loss Measurement Images

Inquiry Cart 0
Send your message to this supplier
 
*From:
*To: Xi'an Xu&Hui Electromechanical Technology Co., Ltd.
*Subject:
*Message:
Characters Remaining: (0/3000)
 
Inquiry Cart 0